AHC810 220 VAC 50-60 Hz Programmable Automatic Control Type Digital Timer Switch
The AHC810 Din rail weekly program digital time switch have a wide screen, display more information, and unit have seven kinds of language to choice.
Description
- Digital time switch
- 44 memory locations
- Language(English/Spain/France/Portugal/Germany/Italy)
- Automatic summer/winter time
EUROPE
Great Britain
U.S.A/Canada
- PIN Code
Display year/month/day/hour/minute
- Built-in lithium battery,power failure memory
- Fully operable without mains connection
- Preset date and time
- Manual ON/OFF control
- Screw terminals
Applications
- Light of billboard or showcase control
- Air-condition or Commercial Refrigeration
- Pumps/Motor/Fan Control
- Hydroponic Systems
- Wastewater Treatment Systems
- Generator Exercising
- Boilers / Heater Control
- Ventilation
- Lighting Panel Control
- Landscape Lighting
- Bug and Pest Control Systems
- Aerobic Waste Water Systems
- General Electrical Circuits
Product Selection
Product Type |
Voltage |
Frequency |
Consumed power |
Terminal |
Channel |
AHC810-220/50Hz |
220V |
50Hz |
4VA |
5 |
1 |
AHC810-220/60Hz |
60Hz |
AHC810-110/50Hz |
110V |
50Hz |
5VA |
AHC810-110/60Hz |
60Hz |
AHC810-12V |
AC/DC 12V |
50/60Hz for AC |
4VA |
AHC810-24V |
AC/DC 24V |
AHC812-220/50Hz |
220V |
50Hz |
7.5VA |
8 |
2 |
AHC812-220/60Hz |
60Hz |
AHC812-110/50Hz |
110V |
50Hz |
AHC812-110/60Hz |
60Hz |
AHC812-12V |
AC/DC 12V |
50/60Hz for AC |
AHC812-24V |
AC/DC 24V |
Technical Data
Operating voltage |
220V AC |
Width |
2 modules |
Installation type |
Din rail |
Type of contact |
Changeover contact |
Switching output |
Phase-independent |
Method of connection terminal |
Screw terminals |
Power reserve |
4 years |
Switching capacity at 250 V AC, cos φ = 1 |
16A |
Switching capacity at 250 V AC, cos φ = 0,6 |
10A |
Incandescent/halogen lamp load 230V |
2600W |
Energy saving lamps |
170W |
LED lamp < 2 W |
30W |
LED lamp 2–8 W |
100W |
LED lamp > 8 W |
120W |
Fluorescent lamp load (electronic ballast) |
650W |
Fluorescent lamp load (conventional) not corrected |
1000VA |
Fluorescent lamp load (conventional)
series-corrected |
1000VA |
Fluorescent lamp load (conventional)
parallel-corrected |
730 VA 80uF |
Time accuracy at 25 °C |
typical ± 2 s/day (quartz) |
Test approval |
CE |
Type of protection |
IP 20 |
Protection class |
II according to EN 60 730-1 |
Housing and insulation material |
High-temperature resistant, self-extinguishing thermoplastic |
Work temperature: |
-10 ~ +50 °C (non-icing) |
Ambient humidity: |
35~85% RH |